{"id":2901,"date":"2026-11-01T23:21:27","date_gmt":"2026-11-01T15:21:27","guid":{"rendered":"https:\/\/igotocableties.com\/?p=2901"},"modified":"2026-10-31T23:43:13","modified_gmt":"2026-10-31T15:43:13","slug":"aerial-support-cable-ties","status":"publish","type":"post","link":"https:\/\/igotocableties.com\/es\/blog\/aerial-support-cable-ties\/","title":{"rendered":"\u00bfPara qu\u00e9 se utilizan las bridas de soporte a\u00e9reo?"},"content":{"rendered":"<p><span style=\"color: #ff0000;\">Bridas de soporte a\u00e9reo <\/span>son productos altamente duraderos dise\u00f1ados para soportar condiciones clim\u00e1ticas adversas. Su funci\u00f3n principal consiste en sujetar cables de telecomunicaciones, coaxiales o de fibra \u00f3ptica en cables de acero colocados en postes de servicios p\u00fablicos. La mayor\u00eda de ellos consta de dos lazos y un peque\u00f1o espaciador producido mediante un proceso de moldeo. De manera sencilla, un lazo envuelve el cable, mientras que el otro se sujeta alrededor del hilo. Con la ayuda del espaciador, los dos no se tocan entre s\u00ed.<\/p>\n<p>Esta gu\u00eda tiene como objetivo educar a las personas sobre las bridas a\u00e9reas, los tipos de bridas m\u00e1s populares utilizados por los trabajadores, los par\u00e1metros importantes de una brida a\u00e9rea, la distancia a la que se deben fijar las bridas a\u00e9reas, as\u00ed como c\u00f3mo determinar si la brida a\u00e9rea resistir\u00e1 condiciones clim\u00e1ticas severas.<\/p>\n<blockquote><p>Una brida de soporte a\u00e9reo, a menudo denominada brida de soporte a\u00e9reo o brida espaciadora a\u00e9rea, es una brida de cable clasificada para exteriores que sirve para sujetar un cable a un hilo mensajero o cualquier otro cable de soporte. Una brida de soporte a\u00e9reo de una sola pieza constar\u00e1 de un lazo de cable, un lazo de hilo y un espaciador incorporado de aproximadamente 12.7 mm (1\/2 pulgada), mientras que un sistema de dos piezas se basa en una brida a\u00e9rea convencional de alta resistencia equipada con un espaciador apilable separado. Dado que las bridas a\u00e9reas se utilizan al aire libre en postes y cables durante muchos a\u00f1os, est\u00e1n fabricadas con nylon 6\/6 estabilizado UV, estabilizado t\u00e9rmicamente y a menudo modificado para impactos o polipropileno resistente a la intemperie, con una temperatura de funcionamiento que var\u00eda de \u221240 \u00b0C a +105 \u00b0C.<\/p><\/blockquote>\n<h2><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2902\" src=\"https:\/\/igotocableties.com\/wp-content\/uploads\/2026\/10\/What-Are-Aerial-Support-Cable-Ties-Used-For.webp\" alt=\"\" width=\"1448\" height=\"1086\" \/><\/h2>\n<h2>\u00bfQu\u00e9 son las Bridas de Soporte A\u00e9reo?<\/h2>\n<p>El cable en las l\u00edneas telef\u00f3nicas a\u00e9reas t\u00edpicas no tiene peso propio. El cable mensajero de acero se sostiene utilizando postes para mantener el cable en su lugar. El cable mensajero puede soportar una carga de aproximadamente 6,000 libras, dependiendo de su grosor.<\/p>\n<p>Un m\u00e9todo de sujeci\u00f3n del cable a\u00e9reo es la brida de soporte a\u00e9reo. Su dise\u00f1o com\u00fan de una sola pieza consta de los siguientes pasos:<\/p>\n<p>La correa envuelve el cable y pasa por la primera ranura de la cabeza para formar el lazo alrededor del cable.<br \/>\nLa correa envuelve el mensajero y pasa por la segunda ranura en la cabeza para completar el lazo alrededor del cable mensajero.<br \/>\nSe crea un espaciador en el dise\u00f1o de la cabeza para mantener el cable alejado del cable mensajero, evitando el desgaste de la funda del cable.<\/p>\n<p>En operaci\u00f3n, las bridas se instalan con el uso de las manos, posiblemente mientras se usan guantes, desde un cami\u00f3n de canasta o una escalera. Por lo tanto, la mayor\u00eda de los dise\u00f1os tienen cabezas grandes y una cola doblada para facilitar la sujeci\u00f3n.<\/p>\n<h2>D\u00f3nde encajan las Bridas en la Planta A\u00e9rea<\/h2>\n<p>Entender lo que las bridas deben y no deben hacer en un camino a\u00e9reo es esencial. Para tramos largos, el proceso habitual sigue siendo el de atado, donde un alambre de atado hecho de acero inoxidable se enrolla continuamente alrededor del cable y el hilo, que generalmente mide entre 0.038 y 0.045 pulgadas. En general, los municipios tendr\u00e1n especificaciones que consideran el alambre de atado como predeterminado y permiten bridas de nylon negro para exteriores como material sustituto siempre que su uso est\u00e9 especificado en un contrato dado.<\/p>\n<p><span style=\"color: #ff0000;\">El hilo mensajero es responsable de llevar la carga en un tramo mientras que la brida no lo es. El papel de la brida es sostener y posicionar el cable correctamente a lo largo del hilo bajo la tensi\u00f3n requerida. Por lo tanto, si un dise\u00f1o requiere bridas para soportar un cable, entonces tal dise\u00f1o es incorrecto y no es la brida.<\/span><\/p>\n<p>Las bridas asumen el control en los puntos donde el amarre es inc\u00f3modo o imposible. En una l\u00ednea de postes t\u00edpica, esos puntos se ven as\u00ed:<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/igotocableties.com\/wp-content\/uploads\/2026\/10\/Where-Cable-Ties-Fit-in-Aerial-Plant.webp\" alt=\"Where aerial support cable ties fit in aerial plant: service drops, expansion loops, splice enclosures and short runs\" \/><figcaption>El alambre de amarre cubre los tramos largos; las bridas y los separadores manejan las ca\u00eddas, bucles, cierres y tramos cortos.<\/figcaption><\/figure>\n<p>Aqu\u00ed est\u00e1 lo que implica cada uno de esos trabajos.<\/p>\n<h3>Ca\u00eddas de Servicio<\/h3>\n<p>La ca\u00edda conectada desde el poste a las instalaciones es el aspecto b\u00e1sico de las instalaciones. El cable de ca\u00edda est\u00e1 anclado al alambre de soporte a trav\u00e9s de bridas de soporte a\u00e9reo.<\/p>\n<h3>Bucles de Expansi\u00f3n en los Postes<\/h3>\n<p>El equipo de instalaci\u00f3n hace bucles de expansi\u00f3n en los postes para que el cable pueda expandirse y ceder cuando el hilo se calienta en verano y se contrae en invierno. Las pautas de instalaci\u00f3n del cable requieren que el bucle sea m\u00e1s del doble de largo que su profundidad, y m\u00e1s del doble de grande que el radio de curvatura m\u00ednimo del cable. Las bridas y los separadores mantienen la forma del bucle y evitan que entre en contacto con el hardware del poste.<\/p>\n<h3>Enclosures de Empalme y Almacenamiento de Holgura<\/h3>\n<p>A medida que la fibra entra en el cierre de empalme a\u00e9reo, necesita ser alimentada en el \u00e1ngulo correcto. Se utiliza una pila de separadores para segregar las entradas de fibra.<\/p>\n<h3>Tramos Cortos y Cable en Figura-8<\/h3>\n<p>Algunas normas establecen que en tramos cortos de interconexi\u00f3n de se\u00f1ales de tr\u00e1fico, se pueden usar bridas bloqueadas o alambre de amarre, donde cualquiera se coloca con un espaciado m\u00e1ximo de 12 pulgadas, o de lo contrario se supone que se deben usar bridas con la instalaci\u00f3n de cable en figura-8.<\/p>\n<h3>Sostenes Temporales y Elevadores<\/h3>\n<p>Tambi\u00e9n es importante sostener el cable temporalmente mediante el uso de bridas de alambre fuertes con resistencia a los UV cuando es necesario amarrar el cable.<\/p>\n<h2>Los Tipos Primarios de Bridas de Soporte A\u00e9reo<\/h2>\n<h3>Bridas de Una Sola Pieza Que Incluyen Separadores Preconstruidos<\/h3>\n<p>Este es el tipo t\u00edpico. Una secci\u00f3n representativa mide 270 mm de longitud y 12.7 mm de ancho, puede sostener paquetes de cables con un di\u00e1metro aproximado de 70 mm, moldeado de nylon 6\/6 estabilizado por calor y UV, modificado por impacto, clasificado de \u221240\u00b0C a +105 \u00b0C. No hay forma de liberar las bridas una vez que est\u00e1n unidas.<\/p>\n<h3>Bridas A\u00e9reas de Polipropileno Releasables<\/h3>\n<p>Una familia diferente utiliza polipropileno resistente a la intemperie con separadores integrados de 1\/2 de largo para adaptarse a l\u00edneas de tama\u00f1o 1\/4 o 5\/16, coaxiales y cables telef\u00f3nicos. Las bridas se pueden desmontar, lo que facilita la disposici\u00f3n de las ca\u00eddas, aunque su tir\u00f3n m\u00ednimo de bucle es inferior a 75 lb, adem\u00e1s las longitudes var\u00edan de 142 mm para un paquete de 25 mm hasta 254 mm para un paquete de 63 mm.<\/p>\n<h3>Bridas Est\u00e1ndar Equipadas Con Separadores<\/h3>\n<p>Una soluci\u00f3n de dos partes utiliza un bloque separador entre dos piezas. Los separadores a\u00e9reos apilables se encajan entre s\u00ed y permiten aumentar el espacio en incrementos de 1\/2 pulgada, lo que es efectivo para conectar puntos o donde varias l\u00edneas se unen a un solo hilo. Los separadores dan forma mientras que las ataduras aportan la resistencia. La gu\u00eda de separadores para ataduras contiene informaci\u00f3n sobre c\u00f3mo corresponder la longitud y el ancho de la atadura con la ranura del separador.<\/p>\n<h3>Ataduras de Acero Inoxidable<\/h3>\n<p>En entornos como \u00e1reas costeras, zonas altamente industrializadas o en condiciones de intenso calor, se debe cambiar a ataduras de acero inoxidable. Tales ataduras resisten la corrosi\u00f3n y los rayos UV, sin embargo, la dificultad de instalaci\u00f3n es mayor en comparaci\u00f3n con todos los otros tipos.<\/p>\n<h2>Especificaciones que realmente importan<\/h2>\n<table>\n<thead>\n<tr>\n<th>Especificaci\u00f3n<\/th>\n<th>Qu\u00e9 buscar<\/th>\n<th>Por qu\u00e9 es importante<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Material<\/td>\n<td>Nylon 6\/6 estabilizado contra UV, estabilizado contra calor, idealmente modificado para impacto; o polipropileno resistente a la intemperie<\/td>\n<td>La luz solar y los ciclos de calor son lo que destruye las ataduras exteriores<\/td>\n<\/tr>\n<tr>\n<td>Color<\/td>\n<td>Negro<\/td>\n<td>El negro de carb\u00f3n es el estabilizador UV en la mayor\u00eda del nylon exterior<\/td>\n<\/tr>\n<tr>\n<td>Ancho<\/td>\n<td>Alrededor de 11 a 12.7 mm en ataduras a\u00e9reas dedicadas<\/td>\n<td>Las correas m\u00e1s anchas distribuyen la carga y resisten la abrasi\u00f3n del viento<\/td>\n<\/tr>\n<tr>\n<td>Tensi\u00f3n<\/td>\n<td>Desde aproximadamente 75 lb (polipropileno) hasta 120 lb y m\u00e1s (nylon 6\/6)<\/td>\n<td>La carga de hielo y el viento a\u00f1aden fuerza muy por encima del peso del cable<\/td>\n<\/tr>\n<tr>\n<td>Temperatura<\/td>\n<td>\u221240 \u00b0C a +105 \u00b0C o mejor<\/td>\n<td>Los hilos bajo el sol del desierto y en inviernos del norte ven ambos extremos<\/td>\n<\/tr>\n<tr>\n<td>Cierre<\/td>\n<td>No liberables para trabajos permanentes; liberables para ca\u00eddas que cambian a menudo<\/td>\n<td>Permanent spans should never rely on a release tab<\/td>\n<\/tr>\n<tr>\n<td>Strap design<\/td>\n<td>Outside serrations<\/td>\n<td>Keeps teeth off the cable jacket<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #ff0000;\">Using common nylon zip ties, white nylon or indoor nylon is never allowed for aerial span applications. Over time, without any UV stabilization, the tie becomes brittle when exposed to sunlight. Snapping of ties 20 feet above dramatically increases the risk of sagging cables which, in turn, will generate the need for locksmithing and additional repairs.<\/span><\/p>\n<p>The absolute minimum for outdoor aerial work is black nylon 6\/6. Some manufacturers state that their specialized ties can last 15 years or more when made of special resins. However, actual conditions will matter, so the performance of aerial ties will depend on the climate. For general outdoor tie work at poles, risers and cabinets, our <a href=\"https:\/\/igotocableties.com\/es\/uv-resistant-cable-tie\/\">bridas negras resistentes a los UV<\/a> are made for solar, telecom and outdoor electrical jobs, and the comparison of the <a href=\"https:\/\/igotocableties.com\/es\/blog\/best-zip-ties-for-outdoor-use-material-uv-resistance\/\">mejores bridas para uso exterior<\/a> covers when to step up to nylon 12 or stainless steel.<\/p>\n<h2>Spacing and Placement<\/h2>\n<p>There is not a conclusive number, which is universally applicable. The cable owner\u2019s construction standards, the utility\u2019s joint-use agreement, and local regulations form the basis of how the spacing is set. Still, some patterns keep on cropping up repeatedly:<\/p>\n<p>Tight spacing on tie-only runs. One interconnect standard required by a public agency states that locking cable ties or lashing wire should be no more than 12 inches apart.<br \/>\nA tie at every transition. Where the cable leaves a strand for a drop, a riser, or closure, place one tie where it makes the departure and another approximately 4 inches from it.<br \/>\nRespect the bend radius. Ties at an expansion loop or closure entry should hold the shape yet not force the cable tighter than its minimum bend radius. Fiber optic cable is especially sensitive to this.<br \/>\nStay clear of the pole hardware. Spacers and tie heads should not rub on bolts, clamps, or guy attachments.<\/p>\n<h2>How to Install Aerial Support Ties<\/h2>\n<p>Once a crew has the rhythm, each tie takes well under a minute. The order never changes: cable first, strand second, spacer in between.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/igotocableties.com\/wp-content\/uploads\/2026\/10\/How-to-Install-Aerial-Support-Ties.webp\" alt=\"How to install aerial support cable ties on a messenger strand step by step\" \/><figcaption>Wrap the cable, wrap the strand, keep the spacer between them, then tension evenly and trim flush.<\/figcaption><\/figure>\n<p>Step by step:<\/p>\n<ol>\n<li>Verify the size of both the strand and the cable. Make sure the diameter of the strand, measured in 1\/4, 5\/16 or 3\/8 inches, and that of the cable lies within the specifications of the tie.<\/li>\n<li>Begin with the cable. Loop the strap around the cable with the prongs outward and pull it through the cable-side of the strap.<\/li>\n<li>Wrap the messenger. Bring the strap around the strand and send the strap through the strand-side of the strap.<\/li>\n<li>Tighten to an appropriate amount. Hand-tighten it till the union cannot slide down the strand anymore. For long linear installations, a tool can apply effective tension as is shown in the guide for <a href=\"https:\/\/igotocableties.com\/es\/blog\/how-to-use-a-zip-tie-gun-for-professional-cable-installation\/\">c\u00f3mo usar una pistola de bridas<\/a>. Overtightening will damage the coaxial cable and perhaps affect its performance.<\/li>\n<li>Cut the excess properly. A long tail will whip in the wind and damage the cable while an uneven one will catch on the gloves during the next job. The tools and technique in <a href=\"https:\/\/igotocableties.com\/es\/blog\/how-to-cut-cable-ties\/\">c\u00f3mo cortar lazos de cable<\/a> leave a smooth edge.<\/li>\n<li>Examine the line visually. Check the installation for proper spacing and orientation and make sure nothing is pinched in the loops or joints.<\/li>\n<\/ol>\n<p>Aerial work close to parked power lines can be done only by licensed personnel who observe the respective regulations and safety rules.<\/p>\n<h2>Choosing Ties for Hot, Cold and Coastal Sites<\/h2>\n<p>The climate plays a greater part in the choice of materials than the majority of the data sheets are willing to acknowledge.<\/p>\n<p>Desert and Gulf temperatures. Constant ultraviolet (UV) light and high temperatures demand the use of UV-stable black nylon and impact-modified plastics to ensure the ties can handle the expansion and contraction caused by daily temperature changes.<br \/>\nCold weather. Nylon becomes less flexible when temperatures drop below freezing. Impact-modified plastics stay tough, and installers must not use ties that have been stored in a truck overnight at freezing temperatures until they warm up.<br \/>\nIce and wind zone. Ice adds weight, wind adds vibration. Therefore, wider straps should be considered, more strict spacing standards adhered to, and tensile load verified.<br \/>\nCoastal and industrial air. All the chemical and salt exposure have to be addressed by the use of stainless steel wire and stainless fasteners at crucial parts and nylon ties for drops and bends.<\/p>\n<p>For pole, riser and cabinet work alongside dedicated aerial ties, a 4.8 mm tie in the 50 lb (22 kg) class, such as our <a href=\"https:\/\/igotocableties.com\/es\/product\/high-strength-cable-tie\/\">brida de cable de alta resistencia<\/a>, handles most small bundles, and our <a href=\"https:\/\/igotocableties.com\/es\/blog\/cable-tie-sizes-a-complete-guide-to-choosing-the-right-dimensions\/\">gu\u00eda de tama\u00f1os de bridas<\/a> helps match longer and wider ties to bigger bundles.<\/p>\n<h2>Common Mistakes on Aerial Runs<\/h2>\n<ul>\n<li>Not enough ties. By increasing spacing beyond the accepted norm, the cable droops in-between ties creating additional loads on them due to wind and ice.<br \/>\nSkipping spacers. Cables pressed directly against strands of steel wear out faster than expected, especially in areas with wind.<br \/>\nOver-tightening coax and fiber. A tie that squashes coax changes its impedance and a tie that applies pressure to fiber creates signal loss.<br \/>\nMixing tie grades in one run. A single natural nylon tie in a series of dark UV ties is the first one to fail.<br \/>\nLeaving long tails. They flap in wind, damage the cable and fail the inspection.<br \/>\nIgnoring the aged ties. An existing run should have failed or damaged ties removed altogether instead of just adding new ones beside them. Our guide on <a href=\"https:\/\/igotocableties.com\/es\/blog\/how-to-remove-cable-ties\/\">c\u00f3mo quitar bridas<\/a> covers cutting them off without nicking the cable.<\/li>\n<\/ul>\n<h2>Inspecting Aerial Ties Over Time<\/h2>\n<p>Once an aerial plant is installed, it is easy to overlook it, which is why tie issues often go unnoticed. Most problems can be caught early simply by checking aerial plant equipment periodically during regular inspections or whenever a crew visits the pole.<\/p>\n<p>Color and texture. Black ties that have turned gray, appear chalky, or have developed fine surface cracks show signs of UV protection failure.<br \/>\nFlexibility. If a tie breaks under light stress, all ties from the same batch should be suspected.<br \/>\nLocation. Ties that have slipped along the span, turned to the point at which the spacer is no longer between the wire and the rod, or moved from where they are supposed to be need adjustment.<br \/>\nJacket damage. The presence of shiny or flattened areas in the vicinity of a tie indicates the presence of vibration-induced friction, which occurs when either the spacer is absent or the tie is not tightened enough.<\/p>\n<p>Ties that have been identified as potentially faulty should be replaced either all at once in one operation or in batches. The date and details of the ties should be logged so that the next crew that arrives knows what has been done.<\/p>\n<h2>Preguntas Frecuentes<\/h2>\n<h3>What are aerial support cable ties used for?<\/h3>\n<p>They connect telephone, fiber optic, coax or a signal cable to a messenger wire between different poles, usually at some service drops, expansion loops, splice chambers or short runs. The integrated spacer keeps the cable away from the steel wire to avoid damage.<\/p>\n<h3>Can I use regular zip ties on a messenger strand?<\/h3>\n<p>Only if the black outdoor ties are UV-stabilized, are of suitable width and strength, and are permitted by the specifications of the cable owner. Indoor-style ties deteriorate under sunlight and are not suitable for outdoor use.<\/p>\n<h3>How far apart should aerial cable ties be?<\/h3>\n<p>Adhere to the construction standard of the cable\u2019s owner or agency. For instance, the public agency\u2019s interconnect standard specifies that ties must not exceed 12 inches apart, and that there must be additional ties wherever the wire leaves the strand at any point.<\/p>\n<h3>Are aerial support ties better than lashing wire?<\/h3>\n<p>Their functions differ. Lashing wire is quicker and the default solution to long distances, while ties are better suited for drops, loops, closures and other short distances where a lashing technique is not viable. Numerous roads use both.<\/p>\n<h3>How long do aerial support ties last outdoors?<\/h3>\n<p>High-grade heat- and UV-stabilized nylon ties are designed for many years outdoors, with some manufacturers claiming 15 years or more. Actual life depends on UV intensity, heat, wind and installation quality, so inspect aerial plant regularly.<\/p>\n<h2>Referencias<\/h2>\n<ul>\n<li><a href=\"https:\/\/en.wikipedia.org\/wiki\/Cable_tie\" rel=\"nofollow noopener\" target=\"_blank\">Brida, Wikipedia<\/a><\/li>\n<li><a href=\"https:\/\/www.fdot.gov\/docs\/default-source\/content-docs\/roadway\/ds\/17\/idx\/17733.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Aerial interconnect design standard, Florida Department of Transportation<\/a><\/li>\n<li><a href=\"https:\/\/www.toronto.ca\/wp-content\/uploads\/2017\/11\/9950-ecs-specs-tcspecs-section-804-100-cables.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Construction specification, Section 804 Cables, City of Toronto<\/a><\/li>\n<li><a href=\"https:\/\/foa.org\/tech\/ref\/OSP_Construction\/Aerial_Workmanship.html\" rel=\"nofollow noopener\" target=\"_blank\">Aerial workmanship, The Fiber Optic Association<\/a><\/li>\n<\/ul>\n<h2>Conclusi\u00f3n<\/h2>\n<p><span style=\"color: #c00000;\">Bridas de soporte a\u00e9reo<\/span> are small parts with a long, exposed working life. The load is carried by the messenger strand while the function of the tie is to hold the cable in position and keep it well spaced throughout the period of the heat wave, ice storms and wind. Use black and UV- and heat-stabilized cable ties of proper width and strength, have the cable properly spaced from the strand with a spacer, stick to the guidelines in your construction code when it comes to spacing specifications, tension the cables without crushing them and cut off the excess tails making them flush. For the standard outdoor ties that support aerial work at poles, risers and cabinets, browse our <a href=\"https:\/\/igotocableties.com\/es\/products\/\">bridas de nylon y pasacables<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Aerial support cable ties are highly durable products designed to withstand harsh weather conditions. Their main function entails fastening telecommunications, coaxial or fiber optic cables on steel cables placed on utility poles. Most of them consist of two loops and a small spacer produced using molding process. Quite simply, one loop wraps around the cable, [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":2902,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2901","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/igotocableties.com\/es\/wp-json\/wp\/v2\/posts\/2901","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/igotocableties.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/igotocableties.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/igotocableties.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/igotocableties.com\/es\/wp-json\/wp\/v2\/comments?post=2901"}],"version-history":[{"count":1,"href":"https:\/\/igotocableties.com\/es\/wp-json\/wp\/v2\/posts\/2901\/revisions"}],"predecessor-version":[{"id":2905,"href":"https:\/\/igotocableties.com\/es\/wp-json\/wp\/v2\/posts\/2901\/revisions\/2905"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/igotocableties.com\/es\/wp-json\/wp\/v2\/media\/2902"}],"wp:attachment":[{"href":"https:\/\/igotocableties.com\/es\/wp-json\/wp\/v2\/media?parent=2901"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/igotocableties.com\/es\/wp-json\/wp\/v2\/categories?post=2901"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/igotocableties.com\/es\/wp-json\/wp\/v2\/tags?post=2901"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}